  1. Dear Fred To change the WB/DB Temperatures of a specific gallery or set of galleries you need to make sure you comply with the following settings: 1. The ED column - heat active (if you haven't deleted the rest of the columns) in your script should say True To achieve this, you can fix a temperature in the gallery or set of galleries where you want to change the temperature in Ventsim and then create your script for that ventsim file. 2. The new temperature settings should be changed in the HI - newfix wb columns and HJ - newfix db. Let me know if that solves your problem. Kind regards.
  2. Dear Xiao Ventsim will calculate them from the setting. You can always double-check by running a summary in the gallery where you have added your heat source or within the information box in thermodynamics.
  3. Dear Asad When modeling a Jet fan is common not to have a Fan Curve; instead the data should be input as Thrust or Quantity or Velocity, this value are normally given by the fan provider in the Equipment's Data Sheet. Within the Fan form, there is a different tab for Jet Fans where you should input the Jet Fan data you have been provided with. Let me know if this solved your problem. Kind regards.
  4. Hi Rodrigo I have checked and the option is available regardless if the fan is currently placed in the model or not. Please feel free to give me a call and we can check together what the issue might be. Kind regards.
  5. Hi Rodrigo You can specify if it's a primary or secondary fan in the fan edit box, next to the rest of the fans settings. Let me know if it worked. Kind regards.
×
×