  1. When assigning Primary and Secondary layers to airways, it sometimes happen that one or more airways are part of more than one vent district or return/intake air system, but we can only assign one primary layer and one secondary layer to an airway. Would it be possible to be able to assign more than one primary or secondary layer to an airway, to have them show when selecting layers similar to assigning more than one stage?
  2. That allows me to change the box sizes, thanks.
  3. Also, the VentLog program keeps crashing after installing it on Win10. Version 2.1.
  4. Hi I'm having issues getting the text to show properly on my VentLog and normal Ventsim files. When changing text size and Ventlog label or text size it doesn't do anything, and the label stays the same size, which is way too big. "Text scale relative" also doesn't do anything anymore. I recently changed to the latest update.
  5. I'm using 5.2.9.4, using the new edit form. I checked it again, and it doesn't seem to be a constant thing. Maybe it's just something I inadvertently changed.
  6. When changing the friction factor of one airway, the resistance type placed on that same airway stays in place, whether it's a custom or pre-set resistance. However, as soon as I highlight more than one airway, and change the friction factor of those airways, all the resistances placed in the airways are deleted, whether it's walls or doors or any custom resistance. This is making it very frustrating when changing the friction factors of multiple airways in a large model at the same time, because all the seals placed along those airways disappear. Is there a reason for this or can it be avoided?
  7. When placing text, it doesn’t have the option to attach to specific layers. For instance, I have my model separated per level with secondary layers. If I place text on a level, and switch the layer off, the text stays visible. So if I have text on 8 different levels, and switch 7 layers off, the text from all the levels stay hanging in the air. How can I link that text to switch off with the layers, or even have text assigned to one specific layer? Also, when I have some text placed on my ventsim model, and I accidently delete the text, the undo button doesn’t bring the text back. Any other airway or something else that I delete can be returned with the undo button but not text. Why is that?
×
×