Hi Martin & Developers
Thanks for the swift reply and patch - the issue appears to be resolved.
I'm aware that secondary fan heat (either via fix flows or from fan curves) is automatically included. For context, the method of using activity tracks to model several heat sources at once is particularly handy in desktop studies of shallow, series-ventilated mines where all the heat reports back to the decline, and ultimately, the bottommost return connection. With minimal error (high strata/broken rock heat load cases excepted), one could simply ignore creating the working levels and the effort involved with constructing ventilation ducts/fans to perform quick heat/energy balances or check where decline conditions exceed some threshold value (e.g. >26.0°Cwb). In my opinion, it is far simpler to create several activity tracks in the appropriate locations and to update equipment counts (e.g. for what-if scenarios) via the track editor compared to manually inserting these heat loads, unless of course the parameter(s) of interest are desired at discreet points.
Keep up the good work.